Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators

This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2022-11
Hauptverfasser: Marsic, Nicolas, Müller, Wolfgang F O, De Gersem, Herbert, Schmelz, Matthias, Zakosarenko, Vyacheslav, Stolz, Ronny, Kurian, Febin, Sieber, Thomas, Schwickert, Marcus
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Marsic, Nicolas
Müller, Wolfgang F O
De Gersem, Herbert
Schmelz, Matthias
Zakosarenko, Vyacheslav
Stolz, Ronny
Kurian, Febin
Sieber, Thomas
Schwickert, Marcus
description This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental properties of the new shield are highlighted. Additionally, this paper compares the volumetric performance of the folded coaxial shield to the one of a ring shield, the latter being installed in many CCCs for measuring particle beam currents in accelerator facilities.
doi_str_mv 10.48550/arxiv.2211.11267
format Article
fullrecord <record><control><sourceid>proquest_arxiv</sourceid><recordid>TN_cdi_arxiv_primary_2211_11267</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2738705046</sourcerecordid><originalsourceid>FETCH-LOGICAL-a526-ce36d8deab34bfd38354e93ef7685ad3bfa2c2dfe0dab76e0aa082f0ee769bc93</originalsourceid><addsrcrecordid>eNot0F9LwzAUBfAgCI65D-CTAZ9b06RJs0cZ_oOhL3svt8nNzOiamrSyfnvr5tOFy48D5xByV7C81FKyR4gn_5NzXhR5UXBVXZEFF6LIdMn5DVmldGCMzX8upViQ-mM8YvQGWgodtFPyiQZHgbrQWrQ0jT1GEzo7msF3e2oCnPyM05fH1s4qUhOnsMfOG2rGGLEbZnTsIcIQYrol1w7ahKv_uyS7l-fd5i3bfr6-b562GUiuMoNCWW0RGlE2zgotZIlrga5SWoIVjQNuuHXILDSVQgbANHcMsVLrxqzFktxfYs_t6z76I8Sp_luhPq8wi4eL6GP4HjEN9SGMca6cal4JXTHJSiV-AV8wYuM</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2738705046</pqid></control><display><type>article</type><title>Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators</title><source>arXiv.org</source><source>Free E- Journals</source><creator>Marsic, Nicolas ; Müller, Wolfgang F O ; De Gersem, Herbert ; Schmelz, Matthias ; Zakosarenko, Vyacheslav ; Stolz, Ronny ; Kurian, Febin ; Sieber, Thomas ; Schwickert, Marcus</creator><creatorcontrib>Marsic, Nicolas ; Müller, Wolfgang F O ; De Gersem, Herbert ; Schmelz, Matthias ; Zakosarenko, Vyacheslav ; Stolz, Ronny ; Kurian, Febin ; Sieber, Thomas ; Schwickert, Marcus</creatorcontrib><description>This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental properties of the new shield are highlighted. Additionally, this paper compares the volumetric performance of the folded coaxial shield to the one of a ring shield, the latter being installed in many CCCs for measuring particle beam currents in accelerator facilities.</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.2211.11267</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Beam currents ; Comparators ; Current comparators ; Mathematical models ; Numerical analysis ; Particle beams ; Physics - Accelerator Physics ; Physics - Instrumentation and Detectors</subject><ispartof>arXiv.org, 2022-11</ispartof><rights>2022. This work is published under http://creativecommons.org/licenses/by-nc-nd/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>http://creativecommons.org/licenses/by-nc-nd/4.0</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>228,230,780,784,885,27925</link.rule.ids><backlink>$$Uhttps://doi.org/10.48550/arXiv.2211.11267$$DView paper in arXiv$$Hfree_for_read</backlink><backlink>$$Uhttps://doi.org/10.1016/j.nima.2018.12.063$$DView published paper (Access to full text may be restricted)$$Hfree_for_read</backlink></links><search><creatorcontrib>Marsic, Nicolas</creatorcontrib><creatorcontrib>Müller, Wolfgang F O</creatorcontrib><creatorcontrib>De Gersem, Herbert</creatorcontrib><creatorcontrib>Schmelz, Matthias</creatorcontrib><creatorcontrib>Zakosarenko, Vyacheslav</creatorcontrib><creatorcontrib>Stolz, Ronny</creatorcontrib><creatorcontrib>Kurian, Febin</creatorcontrib><creatorcontrib>Sieber, Thomas</creatorcontrib><creatorcontrib>Schwickert, Marcus</creatorcontrib><title>Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators</title><title>arXiv.org</title><description>This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental properties of the new shield are highlighted. Additionally, this paper compares the volumetric performance of the folded coaxial shield to the one of a ring shield, the latter being installed in many CCCs for measuring particle beam currents in accelerator facilities.</description><subject>Beam currents</subject><subject>Comparators</subject><subject>Current comparators</subject><subject>Mathematical models</subject><subject>Numerical analysis</subject><subject>Particle beams</subject><subject>Physics - Accelerator Physics</subject><subject>Physics - Instrumentation and Detectors</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GOX</sourceid><recordid>eNot0F9LwzAUBfAgCI65D-CTAZ9b06RJs0cZ_oOhL3svt8nNzOiamrSyfnvr5tOFy48D5xByV7C81FKyR4gn_5NzXhR5UXBVXZEFF6LIdMn5DVmldGCMzX8upViQ-mM8YvQGWgodtFPyiQZHgbrQWrQ0jT1GEzo7msF3e2oCnPyM05fH1s4qUhOnsMfOG2rGGLEbZnTsIcIQYrol1w7ahKv_uyS7l-fd5i3bfr6-b562GUiuMoNCWW0RGlE2zgotZIlrga5SWoIVjQNuuHXILDSVQgbANHcMsVLrxqzFktxfYs_t6z76I8Sp_luhPq8wi4eL6GP4HjEN9SGMca6cal4JXTHJSiV-AV8wYuM</recordid><startdate>20221121</startdate><enddate>20221121</enddate><creator>Marsic, Nicolas</creator><creator>Müller, Wolfgang F O</creator><creator>De Gersem, Herbert</creator><creator>Schmelz, Matthias</creator><creator>Zakosarenko, Vyacheslav</creator><creator>Stolz, Ronny</creator><creator>Kurian, Febin</creator><creator>Sieber, Thomas</creator><creator>Schwickert, Marcus</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>GOX</scope></search><sort><creationdate>20221121</creationdate><title>Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators</title><author>Marsic, Nicolas ; Müller, Wolfgang F O ; De Gersem, Herbert ; Schmelz, Matthias ; Zakosarenko, Vyacheslav ; Stolz, Ronny ; Kurian, Febin ; Sieber, Thomas ; Schwickert, Marcus</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a526-ce36d8deab34bfd38354e93ef7685ad3bfa2c2dfe0dab76e0aa082f0ee769bc93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Beam currents</topic><topic>Comparators</topic><topic>Current comparators</topic><topic>Mathematical models</topic><topic>Numerical analysis</topic><topic>Particle beams</topic><topic>Physics - Accelerator Physics</topic><topic>Physics - Instrumentation and Detectors</topic><toplevel>online_resources</toplevel><creatorcontrib>Marsic, Nicolas</creatorcontrib><creatorcontrib>Müller, Wolfgang F O</creatorcontrib><creatorcontrib>De Gersem, Herbert</creatorcontrib><creatorcontrib>Schmelz, Matthias</creatorcontrib><creatorcontrib>Zakosarenko, Vyacheslav</creatorcontrib><creatorcontrib>Stolz, Ronny</creatorcontrib><creatorcontrib>Kurian, Febin</creatorcontrib><creatorcontrib>Sieber, Thomas</creatorcontrib><creatorcontrib>Schwickert, Marcus</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection><collection>arXiv.org</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marsic, Nicolas</au><au>Müller, Wolfgang F O</au><au>De Gersem, Herbert</au><au>Schmelz, Matthias</au><au>Zakosarenko, Vyacheslav</au><au>Stolz, Ronny</au><au>Kurian, Febin</au><au>Sieber, Thomas</au><au>Schwickert, Marcus</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators</atitle><jtitle>arXiv.org</jtitle><date>2022-11-21</date><risdate>2022</risdate><eissn>2331-8422</eissn><abstract>This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental properties of the new shield are highlighted. Additionally, this paper compares the volumetric performance of the folded coaxial shield to the one of a ring shield, the latter being installed in many CCCs for measuring particle beam currents in accelerator facilities.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.2211.11267</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2022-11
issn 2331-8422
language eng
recordid cdi_arxiv_primary_2211_11267
source arXiv.org; Free E- Journals
subjects Beam currents
Comparators
Current comparators
Mathematical models
Numerical analysis
Particle beams
Physics - Accelerator Physics
Physics - Instrumentation and Detectors
title Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T11%3A10%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_arxiv&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Numerical%20analysis%20of%20a%20folded%20superconducting%20coaxial%20shield%20for%20cryogenic%20current%20comparators&rft.jtitle=arXiv.org&rft.au=Marsic,%20Nicolas&rft.date=2022-11-21&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.2211.11267&rft_dat=%3Cproquest_arxiv%3E2738705046%3C/proquest_arxiv%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2738705046&rft_id=info:pmid/&rfr_iscdi=true