Estimating Respiratory Rate From Breath Audio Obtained Through Wearable Microphones

Respiratory rate (RR) is a clinical metric used to assess overall health and physical fitness. An individual's RR can change from their baseline due to chronic illness symptoms (e.g., asthma, congestive heart failure), acute illness (e.g., breathlessness due to infection), and over the course o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kumar, Agni, Mitra, Vikramjit, Oliver, Carolyn, Ullal, Adeeti, Biddulph, Matt, Mance, Irida
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Kumar, Agni
Mitra, Vikramjit
Oliver, Carolyn
Ullal, Adeeti
Biddulph, Matt
Mance, Irida
description Respiratory rate (RR) is a clinical metric used to assess overall health and physical fitness. An individual's RR can change from their baseline due to chronic illness symptoms (e.g., asthma, congestive heart failure), acute illness (e.g., breathlessness due to infection), and over the course of the day due to physical exhaustion during heightened exertion. Remote estimation of RR can offer a cost-effective method to track disease progression and cardio-respiratory fitness over time. This work investigates a model-driven approach to estimate RR from short audio segments obtained after physical exertion in healthy adults. Data was collected from 21 individuals using microphone-enabled, near-field headphones before, during, and after strenuous exercise. RR was manually annotated by counting perceived inhalations and exhalations. A multi-task Long-Short Term Memory (LSTM) network with convolutional layers was implemented to process mel-filterbank energies, estimate RR in varying background noise conditions, and predict heavy breathing, indicated by an RR of more than 25 breaths per minute. The multi-task model performs both classification and regression tasks and leverages a mixture of loss functions. It was observed that RR can be estimated with a concordance correlation coefficient (CCC) of 0.76 and a mean squared error (MSE) of 0.2, demonstrating that audio can be a viable signal for approximating RR.
doi_str_mv 10.48550/arxiv.2107.14028
format Article
fullrecord <record><control><sourceid>arxiv_GOX</sourceid><recordid>TN_cdi_arxiv_primary_2107_14028</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2107_14028</sourcerecordid><originalsourceid>FETCH-LOGICAL-a678-458480c7559b43b95d940bd29e74f3bac2c04961f88979caaa2960227e038b8e3</originalsourceid><addsrcrecordid>eNotz09PwjAYgPFeOBjwA3iyX2Cz65-1PSIBNcGQ4BKPy9vtHWsC69IVI99eRU7P7Ul-hDwULJdGKfYE8dt_5bxgOi8k4-aOfKyn5E-Q_HCge5xGHyGFeKF7SEg3MZzoc0RIPV2eWx_oziXwA7a06mM4H3r6iRDBHZG--yaGsQ8DTgsy6-A44f2tc1Jt1tXqNdvuXt5Wy20GpTaZVEYa1milrJPCWdVayVzLLWrZCQcNb5i0ZdEZY7VtAIDbknGukQnjDIo5efzfXlX1GH8d8VL_6eqrTvwAK9JKHQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Estimating Respiratory Rate From Breath Audio Obtained Through Wearable Microphones</title><source>arXiv.org</source><creator>Kumar, Agni ; Mitra, Vikramjit ; Oliver, Carolyn ; Ullal, Adeeti ; Biddulph, Matt ; Mance, Irida</creator><creatorcontrib>Kumar, Agni ; Mitra, Vikramjit ; Oliver, Carolyn ; Ullal, Adeeti ; Biddulph, Matt ; Mance, Irida</creatorcontrib><description>Respiratory rate (RR) is a clinical metric used to assess overall health and physical fitness. An individual's RR can change from their baseline due to chronic illness symptoms (e.g., asthma, congestive heart failure), acute illness (e.g., breathlessness due to infection), and over the course of the day due to physical exhaustion during heightened exertion. Remote estimation of RR can offer a cost-effective method to track disease progression and cardio-respiratory fitness over time. This work investigates a model-driven approach to estimate RR from short audio segments obtained after physical exertion in healthy adults. Data was collected from 21 individuals using microphone-enabled, near-field headphones before, during, and after strenuous exercise. RR was manually annotated by counting perceived inhalations and exhalations. A multi-task Long-Short Term Memory (LSTM) network with convolutional layers was implemented to process mel-filterbank energies, estimate RR in varying background noise conditions, and predict heavy breathing, indicated by an RR of more than 25 breaths per minute. The multi-task model performs both classification and regression tasks and leverages a mixture of loss functions. It was observed that RR can be estimated with a concordance correlation coefficient (CCC) of 0.76 and a mean squared error (MSE) of 0.2, demonstrating that audio can be a viable signal for approximating RR.</description><identifier>DOI: 10.48550/arxiv.2107.14028</identifier><language>eng</language><subject>Computer Science - Artificial Intelligence ; Computer Science - Learning ; Computer Science - Sound</subject><creationdate>2021-07</creationdate><rights>http://creativecommons.org/licenses/by/4.0</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>228,230,780,885</link.rule.ids><linktorsrc>$$Uhttps://arxiv.org/abs/2107.14028$$EView_record_in_Cornell_University$$FView_record_in_$$GCornell_University$$Hfree_for_read</linktorsrc><backlink>$$Uhttps://doi.org/10.48550/arXiv.2107.14028$$DView paper in arXiv$$Hfree_for_read</backlink></links><search><creatorcontrib>Kumar, Agni</creatorcontrib><creatorcontrib>Mitra, Vikramjit</creatorcontrib><creatorcontrib>Oliver, Carolyn</creatorcontrib><creatorcontrib>Ullal, Adeeti</creatorcontrib><creatorcontrib>Biddulph, Matt</creatorcontrib><creatorcontrib>Mance, Irida</creatorcontrib><title>Estimating Respiratory Rate From Breath Audio Obtained Through Wearable Microphones</title><description>Respiratory rate (RR) is a clinical metric used to assess overall health and physical fitness. An individual's RR can change from their baseline due to chronic illness symptoms (e.g., asthma, congestive heart failure), acute illness (e.g., breathlessness due to infection), and over the course of the day due to physical exhaustion during heightened exertion. Remote estimation of RR can offer a cost-effective method to track disease progression and cardio-respiratory fitness over time. This work investigates a model-driven approach to estimate RR from short audio segments obtained after physical exertion in healthy adults. Data was collected from 21 individuals using microphone-enabled, near-field headphones before, during, and after strenuous exercise. RR was manually annotated by counting perceived inhalations and exhalations. A multi-task Long-Short Term Memory (LSTM) network with convolutional layers was implemented to process mel-filterbank energies, estimate RR in varying background noise conditions, and predict heavy breathing, indicated by an RR of more than 25 breaths per minute. The multi-task model performs both classification and regression tasks and leverages a mixture of loss functions. It was observed that RR can be estimated with a concordance correlation coefficient (CCC) of 0.76 and a mean squared error (MSE) of 0.2, demonstrating that audio can be a viable signal for approximating RR.</description><subject>Computer Science - Artificial Intelligence</subject><subject>Computer Science - Learning</subject><subject>Computer Science - Sound</subject><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>GOX</sourceid><recordid>eNotz09PwjAYgPFeOBjwA3iyX2Cz65-1PSIBNcGQ4BKPy9vtHWsC69IVI99eRU7P7Ul-hDwULJdGKfYE8dt_5bxgOi8k4-aOfKyn5E-Q_HCge5xGHyGFeKF7SEg3MZzoc0RIPV2eWx_oziXwA7a06mM4H3r6iRDBHZG--yaGsQ8DTgsy6-A44f2tc1Jt1tXqNdvuXt5Wy20GpTaZVEYa1milrJPCWdVayVzLLWrZCQcNb5i0ZdEZY7VtAIDbknGukQnjDIo5efzfXlX1GH8d8VL_6eqrTvwAK9JKHQ</recordid><startdate>20210728</startdate><enddate>20210728</enddate><creator>Kumar, Agni</creator><creator>Mitra, Vikramjit</creator><creator>Oliver, Carolyn</creator><creator>Ullal, Adeeti</creator><creator>Biddulph, Matt</creator><creator>Mance, Irida</creator><scope>AKY</scope><scope>GOX</scope></search><sort><creationdate>20210728</creationdate><title>Estimating Respiratory Rate From Breath Audio Obtained Through Wearable Microphones</title><author>Kumar, Agni ; Mitra, Vikramjit ; Oliver, Carolyn ; Ullal, Adeeti ; Biddulph, Matt ; Mance, Irida</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a678-458480c7559b43b95d940bd29e74f3bac2c04961f88979caaa2960227e038b8e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Computer Science - Artificial Intelligence</topic><topic>Computer Science - Learning</topic><topic>Computer Science - Sound</topic><toplevel>online_resources</toplevel><creatorcontrib>Kumar, Agni</creatorcontrib><creatorcontrib>Mitra, Vikramjit</creatorcontrib><creatorcontrib>Oliver, Carolyn</creatorcontrib><creatorcontrib>Ullal, Adeeti</creatorcontrib><creatorcontrib>Biddulph, Matt</creatorcontrib><creatorcontrib>Mance, Irida</creatorcontrib><collection>arXiv Computer Science</collection><collection>arXiv.org</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kumar, Agni</au><au>Mitra, Vikramjit</au><au>Oliver, Carolyn</au><au>Ullal, Adeeti</au><au>Biddulph, Matt</au><au>Mance, Irida</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimating Respiratory Rate From Breath Audio Obtained Through Wearable Microphones</atitle><date>2021-07-28</date><risdate>2021</risdate><abstract>Respiratory rate (RR) is a clinical metric used to assess overall health and physical fitness. An individual's RR can change from their baseline due to chronic illness symptoms (e.g., asthma, congestive heart failure), acute illness (e.g., breathlessness due to infection), and over the course of the day due to physical exhaustion during heightened exertion. Remote estimation of RR can offer a cost-effective method to track disease progression and cardio-respiratory fitness over time. This work investigates a model-driven approach to estimate RR from short audio segments obtained after physical exertion in healthy adults. Data was collected from 21 individuals using microphone-enabled, near-field headphones before, during, and after strenuous exercise. RR was manually annotated by counting perceived inhalations and exhalations. A multi-task Long-Short Term Memory (LSTM) network with convolutional layers was implemented to process mel-filterbank energies, estimate RR in varying background noise conditions, and predict heavy breathing, indicated by an RR of more than 25 breaths per minute. The multi-task model performs both classification and regression tasks and leverages a mixture of loss functions. It was observed that RR can be estimated with a concordance correlation coefficient (CCC) of 0.76 and a mean squared error (MSE) of 0.2, demonstrating that audio can be a viable signal for approximating RR.</abstract><doi>10.48550/arxiv.2107.14028</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.48550/arxiv.2107.14028
ispartof
issn
language eng
recordid cdi_arxiv_primary_2107_14028
source arXiv.org
subjects Computer Science - Artificial Intelligence
Computer Science - Learning
Computer Science - Sound
title Estimating Respiratory Rate From Breath Audio Obtained Through Wearable Microphones
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T01%3A08%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-arxiv_GOX&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimating%20Respiratory%20Rate%20From%20Breath%20Audio%20Obtained%20Through%20Wearable%20Microphones&rft.au=Kumar,%20Agni&rft.date=2021-07-28&rft_id=info:doi/10.48550/arxiv.2107.14028&rft_dat=%3Carxiv_GOX%3E2107_14028%3C/arxiv_GOX%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true