Interception efficiency of CVM-based lightning protection systems for buildings and the fractional Poisson model

The purpose of this paper is to resolve a question regarding efficiency of a lightning protection system (LPS) for buildings based on the collection volume method (CVM) . The paper has two components. The first, following suggestions of other authors [Abidin and Ibrahim 2004], takes advantage of cou...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Haller, Harold S, Woyczynski, Wojbor A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Haller, Harold S
Woyczynski, Wojbor A
description The purpose of this paper is to resolve a question regarding efficiency of a lightning protection system (LPS) for buildings based on the collection volume method (CVM) . The paper has two components. The first, following suggestions of other authors [Abidin and Ibrahim 2004], takes advantage of count data from installed devices, and independent installation-site inspections to develop our statistical analysis. The second component investigates the validity of the underlying theory by introducing a novel methodology of fractional Poisson processes, which are able to reproduce the burstiness of lightning strikes, an essential feature of stochastic time dependence of incidence of lightning strikes. The standard Poisson processes used in the past efforts in this area cannot do that.
doi_str_mv 10.48550/arxiv.1602.01395
format Article
fullrecord <record><control><sourceid>arxiv_GOX</sourceid><recordid>TN_cdi_arxiv_primary_1602_01395</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1602_01395</sourcerecordid><originalsourceid>FETCH-LOGICAL-a675-dc0d44527c30e97b2eabc76a501ceb6f8a0f1f0cf680904d8beffd92144e5e743</originalsourceid><addsrcrecordid>eNotj7tOwzAYhb0woMIDMOEXSLAT20lGFHGpVFSGijXy5XdrKbEj2yDy9oTAdIZz0fkQuqOkZC3n5EHGb_dVUkGqktC649do3vsMUcOcXfAYrHXagdcLDhb3H2-FkgkMHt35kr3zZzzHkEFv4bSkDFPCNkSsPt1oVj9h6Q3OF8A2yi0mR_weXEprYQoGxht0ZeWY4PZfd-j0_HTqX4vD8WXfPx4KKRpeGE0MY7xqdE2ga1QFUulGSE6oBiVsK4mllmgrWtIRZlq1XjddRRkDDg2rd-j-b3ZDHuboJhmX4Rd92NDrH8XSVvo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Interception efficiency of CVM-based lightning protection systems for buildings and the fractional Poisson model</title><source>arXiv.org</source><creator>Haller, Harold S ; Woyczynski, Wojbor A</creator><creatorcontrib>Haller, Harold S ; Woyczynski, Wojbor A</creatorcontrib><description>The purpose of this paper is to resolve a question regarding efficiency of a lightning protection system (LPS) for buildings based on the collection volume method (CVM) . The paper has two components. The first, following suggestions of other authors [Abidin and Ibrahim 2004], takes advantage of count data from installed devices, and independent installation-site inspections to develop our statistical analysis. The second component investigates the validity of the underlying theory by introducing a novel methodology of fractional Poisson processes, which are able to reproduce the burstiness of lightning strikes, an essential feature of stochastic time dependence of incidence of lightning strikes. The standard Poisson processes used in the past efforts in this area cannot do that.</description><identifier>DOI: 10.48550/arxiv.1602.01395</identifier><language>eng</language><subject>Physics - Geophysics ; Physics - Instrumentation and Methods for Astrophysics</subject><creationdate>2016-01</creationdate><rights>http://arxiv.org/licenses/nonexclusive-distrib/1.0</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>228,230,780,885</link.rule.ids><linktorsrc>$$Uhttps://arxiv.org/abs/1602.01395$$EView_record_in_Cornell_University$$FView_record_in_$$GCornell_University$$Hfree_for_read</linktorsrc><backlink>$$Uhttps://doi.org/10.48550/arXiv.1602.01395$$DView paper in arXiv$$Hfree_for_read</backlink></links><search><creatorcontrib>Haller, Harold S</creatorcontrib><creatorcontrib>Woyczynski, Wojbor A</creatorcontrib><title>Interception efficiency of CVM-based lightning protection systems for buildings and the fractional Poisson model</title><description>The purpose of this paper is to resolve a question regarding efficiency of a lightning protection system (LPS) for buildings based on the collection volume method (CVM) . The paper has two components. The first, following suggestions of other authors [Abidin and Ibrahim 2004], takes advantage of count data from installed devices, and independent installation-site inspections to develop our statistical analysis. The second component investigates the validity of the underlying theory by introducing a novel methodology of fractional Poisson processes, which are able to reproduce the burstiness of lightning strikes, an essential feature of stochastic time dependence of incidence of lightning strikes. The standard Poisson processes used in the past efforts in this area cannot do that.</description><subject>Physics - Geophysics</subject><subject>Physics - Instrumentation and Methods for Astrophysics</subject><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>GOX</sourceid><recordid>eNotj7tOwzAYhb0woMIDMOEXSLAT20lGFHGpVFSGijXy5XdrKbEj2yDy9oTAdIZz0fkQuqOkZC3n5EHGb_dVUkGqktC649do3vsMUcOcXfAYrHXagdcLDhb3H2-FkgkMHt35kr3zZzzHkEFv4bSkDFPCNkSsPt1oVj9h6Q3OF8A2yi0mR_weXEprYQoGxht0ZeWY4PZfd-j0_HTqX4vD8WXfPx4KKRpeGE0MY7xqdE2ga1QFUulGSE6oBiVsK4mllmgrWtIRZlq1XjddRRkDDg2rd-j-b3ZDHuboJhmX4Rd92NDrH8XSVvo</recordid><startdate>20160131</startdate><enddate>20160131</enddate><creator>Haller, Harold S</creator><creator>Woyczynski, Wojbor A</creator><scope>GOX</scope></search><sort><creationdate>20160131</creationdate><title>Interception efficiency of CVM-based lightning protection systems for buildings and the fractional Poisson model</title><author>Haller, Harold S ; Woyczynski, Wojbor A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a675-dc0d44527c30e97b2eabc76a501ceb6f8a0f1f0cf680904d8beffd92144e5e743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Physics - Geophysics</topic><topic>Physics - Instrumentation and Methods for Astrophysics</topic><toplevel>online_resources</toplevel><creatorcontrib>Haller, Harold S</creatorcontrib><creatorcontrib>Woyczynski, Wojbor A</creatorcontrib><collection>arXiv.org</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Haller, Harold S</au><au>Woyczynski, Wojbor A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Interception efficiency of CVM-based lightning protection systems for buildings and the fractional Poisson model</atitle><date>2016-01-31</date><risdate>2016</risdate><abstract>The purpose of this paper is to resolve a question regarding efficiency of a lightning protection system (LPS) for buildings based on the collection volume method (CVM) . The paper has two components. The first, following suggestions of other authors [Abidin and Ibrahim 2004], takes advantage of count data from installed devices, and independent installation-site inspections to develop our statistical analysis. The second component investigates the validity of the underlying theory by introducing a novel methodology of fractional Poisson processes, which are able to reproduce the burstiness of lightning strikes, an essential feature of stochastic time dependence of incidence of lightning strikes. The standard Poisson processes used in the past efforts in this area cannot do that.</abstract><doi>10.48550/arxiv.1602.01395</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.48550/arxiv.1602.01395
ispartof
issn
language eng
recordid cdi_arxiv_primary_1602_01395
source arXiv.org
subjects Physics - Geophysics
Physics - Instrumentation and Methods for Astrophysics
title Interception efficiency of CVM-based lightning protection systems for buildings and the fractional Poisson model
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T07%3A24%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-arxiv_GOX&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Interception%20efficiency%20of%20CVM-based%20lightning%20protection%20systems%20for%20buildings%20and%20the%20fractional%20Poisson%20model&rft.au=Haller,%20Harold%20S&rft.date=2016-01-31&rft_id=info:doi/10.48550/arxiv.1602.01395&rft_dat=%3Carxiv_GOX%3E1602_01395%3C/arxiv_GOX%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true