The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars

Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2012-04
Hauptverfasser: Martin-Carrillo, A, Kirsch, M G F, Caballero, I, Freyberg, M J, Ibarra, A, Kendziorra, E, Lammers, U, Mukerjee, K, Schönherr, G, Stuhlinger, M, Saxton, R D, Staubert, R, Suchy, S, Wellbrock, A, Webb, N, Guainazzi, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Martin-Carrillo, A
Kirsch, M G F
Caballero, I
Freyberg, M J
Ibarra, A
Kendziorra, E
Lammers, U
Mukerjee, K
Schönherr, G
Stuhlinger, M
Saxton, R D
Staubert, R
Suchy, S
Wellbrock, A
Webb, N
Guainazzi, M
description Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with \chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.
doi_str_mv 10.48550/arxiv.1204.0978
format Article
fullrecord <record><control><sourceid>proquest_arxiv</sourceid><recordid>TN_cdi_arxiv_primary_1204_0978</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2082452211</sourcerecordid><originalsourceid>FETCH-LOGICAL-a511-9c60f8f22a3c2279afe9702bfec2817c3774f49a493dc5a72aea4103addca5983</originalsourceid><addsrcrecordid>eNo1kDFPwzAQRi0kJKrSnQlZYiXFPtt1MqKoQKUWGDp0i66ODamSODgJ0JVfTtrCdDrpfd-dHiFXnE1lrBS7w_BdfE45MDlliY7PyAiE4FEsAS7IpG13jDGYaVBKjMjP-t3SYEvsik9Lsc4pbltf9p2lXVEV9RtFY_qAZk-9o90Az18XadTU1GBlA1Jf081qFT3br87Xt9QFX9FNFHBPm75sh1pft__RNOD2eMMPWzgBob0k5w7L1k7-5pisH-br9Clavjwu0vtlhIrzKDEz5mIHgMIA6ASdTTSDrbMGYq6N0Fo6maBMRG4UakCLkjOBeW5QJbEYk-tT7dFP1oSiwrDPDp6yg6cBuDkBTfAfvW27bOf7UA8vZcBikAqAc_EL3MlrTA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2082452211</pqid></control><display><type>article</type><title>The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars</title><source>arXiv.org</source><source>Free E- Journals</source><creator>Martin-Carrillo, A ; Kirsch, M G F ; Caballero, I ; Freyberg, M J ; Ibarra, A ; Kendziorra, E ; Lammers, U ; Mukerjee, K ; Schönherr, G ; Stuhlinger, M ; Saxton, R D ; Staubert, R ; Suchy, S ; Wellbrock, A ; Webb, N ; Guainazzi, M</creator><creatorcontrib>Martin-Carrillo, A ; Kirsch, M G F ; Caballero, I ; Freyberg, M J ; Ibarra, A ; Kendziorra, E ; Lammers, U ; Mukerjee, K ; Schönherr, G ; Stuhlinger, M ; Saxton, R D ; Staubert, R ; Suchy, S ; Wellbrock, A ; Webb, N ; Guainazzi, M</creatorcontrib><description>Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with \chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.1204.0978</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Accuracy ; Calibration ; Light curve ; Observatories ; Physics - High Energy Astrophysical Phenomena ; Physics - Instrumentation and Methods for Astrophysics ; Pulsars ; Radio ; XMM (spacecraft)</subject><ispartof>arXiv.org, 2012-04</ispartof><rights>2012. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>http://arxiv.org/licenses/nonexclusive-distrib/1.0</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>228,230,780,784,885,27925</link.rule.ids><backlink>$$Uhttps://doi.org/10.48550/arXiv.1204.0978$$DView paper in arXiv$$Hfree_for_read</backlink><backlink>$$Uhttps://doi.org/10.1051/0004-6361/201116576$$DView published paper (Access to full text may be restricted)$$Hfree_for_read</backlink></links><search><creatorcontrib>Martin-Carrillo, A</creatorcontrib><creatorcontrib>Kirsch, M G F</creatorcontrib><creatorcontrib>Caballero, I</creatorcontrib><creatorcontrib>Freyberg, M J</creatorcontrib><creatorcontrib>Ibarra, A</creatorcontrib><creatorcontrib>Kendziorra, E</creatorcontrib><creatorcontrib>Lammers, U</creatorcontrib><creatorcontrib>Mukerjee, K</creatorcontrib><creatorcontrib>Schönherr, G</creatorcontrib><creatorcontrib>Stuhlinger, M</creatorcontrib><creatorcontrib>Saxton, R D</creatorcontrib><creatorcontrib>Staubert, R</creatorcontrib><creatorcontrib>Suchy, S</creatorcontrib><creatorcontrib>Wellbrock, A</creatorcontrib><creatorcontrib>Webb, N</creatorcontrib><creatorcontrib>Guainazzi, M</creatorcontrib><title>The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars</title><title>arXiv.org</title><description>Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with \chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.</description><subject>Accuracy</subject><subject>Calibration</subject><subject>Light curve</subject><subject>Observatories</subject><subject>Physics - High Energy Astrophysical Phenomena</subject><subject>Physics - Instrumentation and Methods for Astrophysics</subject><subject>Pulsars</subject><subject>Radio</subject><subject>XMM (spacecraft)</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GOX</sourceid><recordid>eNo1kDFPwzAQRi0kJKrSnQlZYiXFPtt1MqKoQKUWGDp0i66ODamSODgJ0JVfTtrCdDrpfd-dHiFXnE1lrBS7w_BdfE45MDlliY7PyAiE4FEsAS7IpG13jDGYaVBKjMjP-t3SYEvsik9Lsc4pbltf9p2lXVEV9RtFY_qAZk-9o90Az18XadTU1GBlA1Jf081qFT3br87Xt9QFX9FNFHBPm75sh1pft__RNOD2eMMPWzgBob0k5w7L1k7-5pisH-br9Clavjwu0vtlhIrzKDEz5mIHgMIA6ASdTTSDrbMGYq6N0Fo6maBMRG4UakCLkjOBeW5QJbEYk-tT7dFP1oSiwrDPDp6yg6cBuDkBTfAfvW27bOf7UA8vZcBikAqAc_EL3MlrTA</recordid><startdate>20120404</startdate><enddate>20120404</enddate><creator>Martin-Carrillo, A</creator><creator>Kirsch, M G F</creator><creator>Caballero, I</creator><creator>Freyberg, M J</creator><creator>Ibarra, A</creator><creator>Kendziorra, E</creator><creator>Lammers, U</creator><creator>Mukerjee, K</creator><creator>Schönherr, G</creator><creator>Stuhlinger, M</creator><creator>Saxton, R D</creator><creator>Staubert, R</creator><creator>Suchy, S</creator><creator>Wellbrock, A</creator><creator>Webb, N</creator><creator>Guainazzi, M</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>GOX</scope></search><sort><creationdate>20120404</creationdate><title>The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars</title><author>Martin-Carrillo, A ; Kirsch, M G F ; Caballero, I ; Freyberg, M J ; Ibarra, A ; Kendziorra, E ; Lammers, U ; Mukerjee, K ; Schönherr, G ; Stuhlinger, M ; Saxton, R D ; Staubert, R ; Suchy, S ; Wellbrock, A ; Webb, N ; Guainazzi, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a511-9c60f8f22a3c2279afe9702bfec2817c3774f49a493dc5a72aea4103addca5983</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Accuracy</topic><topic>Calibration</topic><topic>Light curve</topic><topic>Observatories</topic><topic>Physics - High Energy Astrophysical Phenomena</topic><topic>Physics - Instrumentation and Methods for Astrophysics</topic><topic>Pulsars</topic><topic>Radio</topic><topic>XMM (spacecraft)</topic><toplevel>online_resources</toplevel><creatorcontrib>Martin-Carrillo, A</creatorcontrib><creatorcontrib>Kirsch, M G F</creatorcontrib><creatorcontrib>Caballero, I</creatorcontrib><creatorcontrib>Freyberg, M J</creatorcontrib><creatorcontrib>Ibarra, A</creatorcontrib><creatorcontrib>Kendziorra, E</creatorcontrib><creatorcontrib>Lammers, U</creatorcontrib><creatorcontrib>Mukerjee, K</creatorcontrib><creatorcontrib>Schönherr, G</creatorcontrib><creatorcontrib>Stuhlinger, M</creatorcontrib><creatorcontrib>Saxton, R D</creatorcontrib><creatorcontrib>Staubert, R</creatorcontrib><creatorcontrib>Suchy, S</creatorcontrib><creatorcontrib>Wellbrock, A</creatorcontrib><creatorcontrib>Webb, N</creatorcontrib><creatorcontrib>Guainazzi, M</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>arXiv.org</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Martin-Carrillo, A</au><au>Kirsch, M G F</au><au>Caballero, I</au><au>Freyberg, M J</au><au>Ibarra, A</au><au>Kendziorra, E</au><au>Lammers, U</au><au>Mukerjee, K</au><au>Schönherr, G</au><au>Stuhlinger, M</au><au>Saxton, R D</au><au>Staubert, R</au><au>Suchy, S</au><au>Wellbrock, A</au><au>Webb, N</au><au>Guainazzi, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars</atitle><jtitle>arXiv.org</jtitle><date>2012-04-04</date><risdate>2012</risdate><eissn>2331-8422</eissn><abstract>Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with \chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.1204.0978</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2012-04
issn 2331-8422
language eng
recordid cdi_arxiv_primary_1204_0978
source arXiv.org; Free E- Journals
subjects Accuracy
Calibration
Light curve
Observatories
Physics - High Energy Astrophysical Phenomena
Physics - Instrumentation and Methods for Astrophysics
Pulsars
Radio
XMM (spacecraft)
title The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T06%3A29%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_arxiv&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20relative%20and%20absolute%20timing%20accuracy%20of%20the%20EPIC-pn%20camera%20on%20XMM-Newton,%20from%20X-ray%20pulsations%20of%20the%20Crab%20and%20other%20pulsars&rft.jtitle=arXiv.org&rft.au=Martin-Carrillo,%20A&rft.date=2012-04-04&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.1204.0978&rft_dat=%3Cproquest_arxiv%3E2082452211%3C/proquest_arxiv%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2082452211&rft_id=info:pmid/&rfr_iscdi=true